134 research outputs found

    Kinematic analysis of handwriting movements in patients with Alzheimer's disease, mild cognitive impairment, depression and healthy subjects

    Get PDF
    A variety of studies have demonstrated that motor disorders, parkinsonism and extrapyramidal motor symptoms (EPMS) are common in patients with Alzheimer's disease (AD). Several studies have reported an association of EPMS with severity, progression and poor prognosis of AD. The majority of these studies used clinical assessments for the rating of EPMS. In this study, kinematic handwriting analysis was used to quantify differences in fine hand motor function in patients with probable AD and mild cognitive impairment (MCl, as an assumed initial stage of AD) compared to depressed patients and healthy controls. Both patients with MCl and patients with probable AD exhibited loss of fine motor performance. Movements of AD patients were significantly less regular than those of healthy controls. Copyright (C) 2003 S. Karger AG, Basel

    Inverse Finite Element Approach to Identify the Post-Necking Hardening Behavior of Polyamide 12 under Uniaxial Tension.

    Get PDF
    Finite-element (FE) simulations that go beyond the linear elastic limit of materials can aid the development of polymeric products such as stretch blow molded angioplasty balloons. The FE model requires the input of an appropriate elastoplastic material model. Up to the onset of necking, the identification of the hardening curve is well established. Subsequently, additional information such as the cross-section and the triaxial stress state inside the specimen is required. The present study aims to inversely identify the post-necking hardening behavior of the semi-crystalline polymer polyamide 12 (PA12) at different temperatures. Our approach uses structural FE simulations of a dog-bone tensile specimen in LS-DYNA with mesh sizes of 1 mm and 2 mm, respectively. The FE simulations are coupled with an optimization routine defined in LS-OPT to identify material properties matching the experimental behavior. A Von Mises yield criterion coupled with a user-defined hardening curve (HC) were considered. Up to the beginning of necking, the Hockett-Sherby hardening law achieved the best fit to the experimental HC. To fit the entire HC until fracture, an extension of the Hockett-Sherby law with power-law functions achieved an excellent fit. Comparing the simulation and the experiment, the following coefficient of determination R2 could be achieved: Group I: R2 > 0.9743; Group II: R2 > 0.9653; Group III: R2 > 0.9927. Using an inverse approach, we were able to determine the deformation behavior of PA12 under uniaxial tension for different temperatures and mathematically describe the HC

    Characterization and modeling of a planar ultrasonic piezoelectric transducer for periodontal scalers

    Get PDF
    Caries and periodontitis affect the majority of adults during their lifetime. Piezoelectric ultrasonic scalers offer great benefits during the prevention and treatment of periodontal diseases. Our group developed a novel ultrasonic periodontal scaler based on a planar piezoelectric transducer. However, similar to other piezoelectric configurations, the transducer’s characteristics are strongly influenced by operation conditions. In this study, we investigated the influence of driving voltage amplitude and loading force applied using physical calculus models on the novel planar transducer’s input impedance and vibration. Our results show that the resonance frequency, i.e. the frequency at which maximal deflection of the tip occurs, decreases with increasing driving voltage amplitude while it increases with increasing force. Additionally, decreasing driving voltage amplitudes and increasing force both increase the minimal magnitude and reduce the maximal phase of the input impedance near resonance. Based on these observations, we developed a procedure to extend the Butterworth-Van-Dyke (BVD) Model. The extended BVD models allow to simulate the transducer in realistic scenarios and may facilitate the development of dedicated control systems for planar piezoelectric transducers

    Development of a Water Transmission Rate (WTR) Measurement System for Implantable Barrier Coatings.

    Get PDF
    While water vapor transmission rate (WVTR) measurement is standardly used to assess material permeability, a system able to quantify liquid water transmission rate (WTR) measurement is highly desirable for implantable thin film barrier coatings. Indeed, since implantable devices are in contact or immersed in body fluids, liquid WTR was carried out to obtain a more realistic measurement of the barrier performance. Parylene is a well-established polymer which is often the material of choice for biomedical encapsulation applications due to its flexibility, biocompatibility, and attractive barrier properties. Four grades of parylene coatings were tested with a newly developed permeation measurement system based on a quadrupole mass spectrometer (QMS) detection method. Successful measurements of gas and water vapor and the water transmission rates of thin parylene films were performed and validated, comparing the results with a standardized method. In addition, the WTR results allowed for the extraction of an acceleration transmission rate factor from the vapor-to-liquid water measurement mode, which varies from 4 to 4.8 between WVTR and WTR. With a WTR of 72.5 µm g m-2 day-1, parylene C displayed the most effective barrier performance

    Safety of Active Implantable Devices during MRI Examinations: A Finite Element Analysis of an Implantable Pump

    Get PDF
    The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safet

    Multi-modales Biofeedback System zur Vorbeugung von Stürzen Multi-modal Biofeedback System for the Prevention of Falls

    Get PDF
    Das Biofeedback des Körperschwankens stellt eine Möglichkeit dar, Patienten mit statischen und dynamischen Gleichgewichtsproblemen alternative Sinnesreize zur Erlangung eines stabilen Gleichgewichts zur Verfügung zu stellen, was zu einer Verbesserung ihrer Lebensqualität führt. Das Biofeedback-System erzeugt mittels am Kopf befestigter Signalwandler auditive, vibro-taktile und vibro-vestibuläre Sinneseindrücke. Die Ergebnisse sowohl an jungen als auch an älteren Probanden ergaben, dass mit Hilfe des Biofeedbacks eine bemerkenswerte 40-60%ige Reduktion des Körperschwankens erzielt werden konnt

    Deep-Learning-Based Segmentation of the Shoulder from MRI with Inference Accuracy Prediction

    Get PDF
    Three-dimensional (3D)-image-based anatomical analysis of rotator cuff tear patients has been proposed as a way to improve repair prognosis analysis to reduce the incidence of postoperative retear. However, for application in clinics, an efficient and robust method for the segmentation of anatomy from MRI is required. We present the use of a deep learning network for automatic segmentation of the humerus, scapula, and rotator cuff muscles with integrated automatic result verification. Trained on N = 111 and tested on N = 60 diagnostic T1-weighted MRI of 76 rotator cuff tear patients acquired from 19 centers, a nnU-Net segmented the anatomy with an average Dice coefficient of 0.91 ± 0.06. For the automatic identification of inaccurate segmentations during the inference procedure, the nnU-Net framework was adapted to allow for the estimation of label-specific network uncertainty directly from its subnetworks. The average Dice coefficient of segmentation results from the subnetworks identified labels requiring segmentation correction with an average sensitivity of 1.0 and a specificity of 0.94. The presented automatic methods facilitate the use of 3D diagnosis in clinical routine by eliminating the need for time-consuming manual segmentation and slice-by-slice segmentation verification

    An Evaluation of Parylene Thin Films to Prevent Encrustation for a Urinary Bladder Pressure MEMS Sensor System

    Get PDF
    Recent developments in urological implants have focused on preventive strategies to mitigate encrustation and biofilm formation. Parylene, a conformal, pinhole-free polymer coating, has gained attention due to its high biocompatibility and chemical resistance, excellent barrier properties, and low friction coefficient. This study aims to evaluate the effectiveness of parylene C in comparison to a parylene VT4 grade coating in preventing encrustation on a urinary bladder pressure MEMS sensor system. Additionally, silicon oxide (SiOx) applied as a finish coating was investigated for further improvements. An in vitro encrustation system mimicking natural urine flow was used to quantify the formation of urinary stones. These stones were subsequently analyzed using Fourier transform infrared spectrometry (FTIR). Encrustation results were then discussed in relation to coating surface chemical properties. Parylene C and VT4 grades demonstrated a very low encrustation mass, making them attractive options for encrustation prevention. The best performance was achieved after the addition of a hydrophilic SiOx finish coating on parylene VT4 grade. Parylene-based encapsulation proved to be an outstanding solution to prevent encrustation for urological implants

    Development and in-vitro characterization of an implantable flow sensing transducer for hydrocephalus

    Get PDF
    An implantable transducer for monitoring the flow of Cerebrospinal fluid (CSF) for the treatment of hydrocephalus has been developed which is based on measuring the heat dissipation of a local thermal source. The transducer uses passive telemetry at 13.56MHz for power supply and read out of the measured flow rate. The in vitro performance of the transducer has been characterized using artificial Cerebrospinal Fluid (CSF) with increased protein concentration and artificial CSF with 10% fresh blood. After fresh blood was added to the artificial CSF a reduction of flow rate has been observed in case that the sensitive surface of the flow sensor is close to the sedimented erythrocytes. An increase of flow rate has been observed in case that the sensitive surface is in contact with the remaining plasma/artificial CSF mix above the sediment which can be explained by an asymmetric flow profile caused by the sedimentation of erythrocythes having increased viscosity compared to artificial CSF. After removal of blood from artificial CSF, no drift could be observed in the transducer measurement which could be associated to a deposition of proteins at the sensitive surface walls of the packaged flow transducer. The flow sensor specification requirement of +−10% for a flow range between 2ml/h and 40ml/h. could be confirmed at test conditions of 37°
    • …
    corecore